July 2013 8.1 Display and operation 1209
You can write-protect lines of the preset table. A write protection for individual
lines or entire areas in the preset table can now be set by an entry of
PR.LINESLOCKED = (e.g. PR.LINESLOCKED = 1,4-8,22 ). Write-protection can be
activated only for the first 255 lines of the preset table. Protected lines are
indicated in the editor by a different color.
MP7294 Disable axis-specific "Datum setting" in the preset table
Format: %xxxxxxxxxxxxxxxxxx
Input: Bits 0 to 17 represent axes 1 to 18
0: Not disabled
1: Disabled
MP7268 Sorting/hiding columns of the preset table
Input: 1 to 99 = Order of the columns
0 = Do not display the column
Set Reset
M4589 Activate datum management via
preset table
NC NC