July 2013 8.1 Display and operation 1255
Status of
Mfunctions
With Module 9060 you can ascertain the status of M functions M100 to
M199.
With Module 9061 the status of the non-modal M functions M94, M142,
M143 and M146 can be ascertained.
Module 9060 M function status
Module 9060 can determine whether an M function between M100 and M199
is active.
Call:
PS B/W/D/K <Number of the M function (100 to 199)>
CM 9060
PL B/W/D <Status>
0: M function inactive
1: M function active
Error code:
Module 9061 Status of non-modal M functions
With Module 9061 the status of the non-modal M functions M94, M142,
M143 and M146 can be interrogated. The status of the interrogated
M function is then set until the module is called again, even if the NC program
has finished.
Call:
PS B/W/D/K <Number of the M function (90 to 199)>
CM 9061
PL B/W/D <Status>
0: M function was not active
1: M function was active
Error code:
Marker Value Meaning
M4203 0 Status was ascertained
1 Error code in W1022
W1022 1 Invalid number of M function
Marker Value Meaning
M4203 0 Status was ascertained
1 Error code in W1022
W1022 1 Invalid number of M function