July 2013 8.1 Display and operation 1261
Standard logo: Enter the keyword LOGO = in OEM.SYS, followed by the
complete path of the logo, e.g. LOGO = PLC:\LOGO\OEM-LOGO.BMP
Logo with service pack installed: Enter the keyword LOGOSP = in OEM.SYS,
followed by the complete path of the logo, e.g. LOGOSP = PLC:\LOGO\SP-
LOGO.BMP
On the TNC, create a new directory, for example PLC:\LOGO.
Transfer the logo to this directory
Shutting down the
control
The control must be shut down before it can be switched off. This is done
either with the soft key in Manual mode or by the PLC with Module 9279 or
9189. If the control is shut down (either with a PLC module or with the soft
key), M4179 is set, the ready signal of the drives is removed, and the hard disk
is set to sleep mode.
If a PLC output is to be set after shutting down the control, this function must
be activated with MP4040 = 1 or 2. Shutting down via Module 9279 must be
done with Mode 2. After the control has been shut down and after the time
from MP4041 has expired, the PLC output specified in MP4044 is set.
PLC outputs of a PL 62xx or an MB machine operating panel can be used for
this function. However, the following must be kept in mind:
The maximum current of an output on a machine operating panel is limited
to 150 mA (500 mA with the PL 62xx).
Galvanic isolation of the PLC supply must be ensured. The machine
operating panels and their outputs are supplied with +24 V NC.
MP4040 Set PLC output after shutdown
Input: 0: Do not set a PLC output
1: Only after shutdown via Module 9279
2: After shutdown via Module 9279 or soft key
MP4041 Time after shutdown until setting of the PLC output from
MP4044
Input: 0 to 1000 [s]
MP4044 PLC output to be set after shutdown
Input: Symbolic name of PLC output
0: Cannot be evaluated, results in an error message
Set Reset
M4179 Control is being shut down NC NC