1262 HEIDENHAIN Technical Manual iTNC 530 HSCI
Module 9279 Shut down control (configurable)
PLC Module 9279 carries out the reset function of the NC. Depending on the
<Mode> parameter, configuration parameters concerning the shutdown
process can be taken into account.
Constraints:
The functionality of the shutdown delay with PLC markers M4195 and
M4197 is not available when shutting down via this module.
Call:
PS B/W/D/K <Mode>
0: Shut down the control without evaluating the MP
configuration for shutting down (MP4040 to MP4042)
1: Shut down and restart the control
2: Shut down the control depending on the MP
configuration for shutting down (MP4040 to MP4042)
CM 9279
Error code:
Module 9189 Shut down the control
Module 9189 shuts down the control. The PLC is not executable after
shutdown. The message windows, which appear during shutdown via soft
key, do not appear.
Call:
CM 9189
Error code:
Marker Value Meaning
M4203 0 Control reset was carried out
1 Error code in W1022
W1022 2 Mode parameter is invalid
20 Call was not in a submit/spawn job
Marker Value Meaning
M4203 0 Control was shut down
1 Error code in W1022
W1022 Module was not called in a spawn job or submit job