EasyManua.ls Logo

HEIDENHAIN iTNC 530 HSCI - Page 1321

HEIDENHAIN iTNC 530 HSCI
1966 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
July 2013 8.1 Display and operation 1321
The detected, actually connected hardware at the HSCI bus (actual
configuration) is displayed. The control also knows from the IOC file the
previously configured hardware configuration to be expected (nominal
configuration). The HSCI bus diagnosis compares the actual configuration to
the nominal configuration and reveals deviations. At HSCI bus positions where
a deviation was found, the actually configured hardware (IOC:) is displayed
behind the detected connected hardware (dialog, e.g. /IOC: MB 620). This
provides you with a direct comparison of the actual configuration and the
nominal configuration in order to support you in finding errors. HSCI
components that are missing from the actual configuration (e.g. due to an
interruption in the HSCI bus) are identified by a corresponding symbol.
Set Reset
M4641 If the marker is set, the HSCI bus
operates without error
NC NC

Table of Contents

Other manuals for HEIDENHAIN iTNC 530 HSCI