July 2013 8.1 Display and operation 1351
Details
Computer: Host name or IP address of the external
computer. In the recommended
configuration of the IPC 6341, it is the IP
address 198.168.254.3.
User name: User name with which the connection
should log in.
Password: The default password for connection to the
VNC server is "123". Please change this
password on the IPC and TNC during
commissioning.
Windows domain Domain of the target computer, if required.
Timeout (sec.): When the TNC shuts down, it commands
the Windows computer to shut down.
Before the TNC displays the message "You
may switch off now", it waits for <Timeout>
seconds. If the Windows computer is
switched off before the <Timeout> seconds
are over, the TNC does not wait any longer.
Force All programs on the Windows computer are
shut down automatically, even if dialogs of
these programs, for example "Save file yes/
no" are still open. If "Force" is not set,
Windows waits for up to 20 seconds. This
delays the shutdown process or the
Windows computer is switched off before
Windows has shut down.
Reboot Reboot the Windows computer.
Run during
restart
Reboot the Windows computer when the
TNC reboots. Only effective if the TNC is
rebooted with the Shutdown icon in the
taskbar at bottom right or if a reboot is
performed due to changes to the system
settings (e.g. network settings).
Run during
switch-off
Switch off the Windows computer when
the TNC is shut down (no reboot). This is
the standard scenario. The END key will
then no longer trigger a reboot, either.
Additional options Advanced settings that are usually not
necessary. Only in consultation with
HEIDENHAIN.
Menu item Function