1356 HEIDENHAIN Technical Manual iTNC 530 HSCI
Module 9082 Display a string in the small PLC window
The string is designated with a string number or is transferred as an immediate
string and ends with the ASCII character <NUL>. It is shown in the small PLC
window in line 0 or 1, with each character in the color given for it. Text strings
with a length of max. 128 characters can be transferred to PLC module 9082
for display in the small PLC window. Depending on the size of the window and
the screen being used, the NC automatically limits the text string to the
maximum number of displayable characters. In the event of error, no string is
shown.
References to PLC dialogs or PLC error messages are executed:
Entered dialog or error number not found:
Is replaced by the ASCII character "@".
Non-displayable character in the text (except string end):
Is replaced by the ASCII character "^".
The character size is oriented to the size of the screen window or by the
current operating mode, and cannot be influenced.
If the specified color number is zero, the text is shown in the same color as
the character last shown. If the first character of a line is specified as zero, the
color is undefined and can change from one display line to another.
Call:
PS K/B/W/D <Line number>
0 or 1
PS K/B/W/D <Column number>
0 to 63
PS K/B/W/D <Number of the color>
0 to 15
PS K/B/W/D/S<String number or string>
CM 9082
Error code:
Column
063
Line 0
Line 1
Marker Value Meaning
M4203 0 No error
1 Call was not in a submit or spawn job
or line less than zero or greater than 1
or Wrong string number or no end of strings
or the last characters of the string can no longer be
displayed in the screen window.