July 2013 8.2 PLC window 1357
Module 9083 Display a moving-bar diagram in the small PLC window
The moving-bar diagram is shown in the specified line with the specified
length and colors.
The diagram can be limited to the left half of each line. In this case the ASCII
text is limited to max. 19 characters of the right half.
The diagram comprises a rectangular frame in the maximum length and height
of an ASCII character. A scale graduation is shown at the top after every ten
units. The bar starts from the left-hand edge of the grid. The unused part of
the grid is filled in with the background color.
If you define the maximum length > 150, the length is limited to 150. If the
current length is > 150, the length is limited to the maximum length.
Color zero uses the background color. The background color of the PLC
window can be used for the margin or scale graduation, for example, if they
are not to be shown.
Call:
PS K/B/W/D <Line number>
0 or 1
PS K/B/W/D <Color for bar>
0 to 15
PS K/B/W/D <Color for margin and scale graduation>
0 to 15
PS K/B/W/D <Current length of the bar>
0 to 150
PS K/B/W/D <Maximum length of the bar>
0 to 150
CM 9083
Error code:
Column 0150 019
Line 0
Line 1
Marker Value Meaning
M4203 0 No error
1 Call was not in a spawn or submit job
or line less than 0 or greater than 1

Table of Contents