Module 9187 Status of a soft-key function call
Immediately after Module 9186 is called, the status 1 (soft-key function not
yet completed) is set—regardless of whether the function can be run in the
current operating mode. Module 9186 cannot be called again until status 0 or
2 is set. The error status 2 is erased if Module 9186 is called again or if power
is switched on.
Call:
CM 9187
PL B/W/D <Status>
0: Soft-key function completed or none called
1: Soft-key function not yet completed
2: Error: Soft-key function cannot be completed because
soft key is not available or operating mode is incorrect
Module 9188 Call a soft-key function
Module 9188 enables you to simulate soft-key functions. The soft-key
designation is used for programming.
Conditions:
For a soft-key function to be simulated the soft key must be contained in the
soft-key row that is displayed on the screen or in one of the soft-key rows
that are in the same level but on the following screen pages.
The parameter Attribute defines whether a function should be activated
although the soft key is not displayed in the soft-key row on the screen, but
is contained in one of the following soft-key rows.
As opposed to module 9186, the status can be determined with error code
W1022 as soon as the module is called.