1418 HEIDENHAIN Technical Manual iTNC 530 HSCI
Module 9251 End the PLC editor for tables
With this module you end the PLC editor and specify whether the changes are
to be put into the original table. The changed values are not checked
automatically. Before calling Module 9251 you can read and check the
temporary file in the PLC.
Call:
PS B/W/D/K <Mode>
0: Do not place changes into the original file
1: Place changes into the original file
CM 9251
Error code:
Module 9252 Position the cursor in the PLC editor
With this module you place the cursor of the PLC editor on a specified line and
in a specified column. The line is defined relative to the starting line of Module
9250. The designated column must be defined in Module 9250.
Call:
PS B/W/D/K/S<String with column name>
PS B/W/D/K <Line>
CM 9252
Error code:
Marker Value Meaning
M4203 0 Editor was opened
1 Error code in W1022
W1022 3 Incorrect value was transferred for mode
6 Changes could not be saved in the original table
20 Module was not called in a spawn job or submit job
28 PLC editor had not been opened with Module 9250
Marker Value Meaning
M4203 0 Cursor was set
1 Error code in W1022
W1022 1 Incorrect line number
3 Incorrect string number
20 Module was not called in a spawn job or submit job
30 Incorrect column name
35 PLC editor is not open (Module 9250)