July 2013 8.13 Touch probe 1539
8.13.2 Touch probe cycles
The probing cycles are available in the Manual Operation and Electronic
Handwheel modes and in the NC program (see the Touch Probe Cycles User's
Manual).
With the machine parameters, adjust the touch probe to the measuring
conditions.
With MP6165, you can specify if during manual measurement and in the
touch probe cycles 0 and 1 the touch probe with infrared transmission is
oriented so that it is always deflected in the same direction.
With MP6166 you can set whether the probing directions is transformed in
the rotated plane in the manual measuring cycles and when basic rotation is
active.
F1 = rapid traverse during probing from the NC program:
MP6150 for triggering touch probe
F2 = probing feed rate:
MP6120 for triggering touch probe
Note
Please note that MP6166 is not in effect for the calibration cycles and the
cycles for determining the basic rotation.
F
1
F
2
F
2
ProbingintheManual
Operation and
El. Handwheel modes
Probing from the NC
program
Setup clearance
(MP6140)
Max. measurin
g range
(MP6130)
Max. measurin
g range
(MP6130)