154 HEIDENHAIN Technical Manual iTNC 530 HSCI
ServiceRequest=[0, 1] A service request is triggered after an update
(only if remote diagnosis is active)
0: No [default]
1: Yes
ConvertToAscii=[0, 1]
(only if Interactive=0)
Binary to ASCII conversion with automated
update process (not with service pack)
0: No
1: Yes [default]
CopyToSys=[0, 1] The setup archive to be installed is copied to the
directory SYS:\zip (iTNC with Windows:
C:\Program Files\install). This makes it possible to
return to this software version later.
0: No
1: Yes [default]
DeleteFiles=
[DATE,SIZE,CANCEL]
(only if Interactive=0)
Procedure during binary to ASCII conversion
during automated update if there is not enough
memory available on the TNC or PLC partition
DATE: Delete oldest files first
SIZE: Delete largest files first
CANCEL: Cancel the update [default]
DeleteArchives=
[DATE,SIZE,CANCEL]
(only if Interactive=0)
Procedure if there is not enough room on the SYS
partition for the update
DATE: Delete oldest archive first
SIZE: Delete largest archive first
CANCEL: Cancel the update [default]
Language=[ENGLISH,
GERMAN]
(only if Confirm=0)
Language for the dialog guidance during the
update if no user activities are required for
starting the update and rebooting (Confirm=0)
GERMAN: German dialog text
ENGLISH: English dialog text [default]
DelSource=[0, 1] Delete the source files (setup.zip, setup.ini,
setup.elf/exe) once the update has completed
successfully
0: No [default]
1: Yes
DeleteIni=[0, 1] Delete the setup.ini file after a successful update.
0: No [default]
1: Yes