EasyManua.ls Logo

HEIDENHAIN iTNC 530 HSCI - Page 1544

HEIDENHAIN iTNC 530 HSCI
1966 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
1544 HEIDENHAIN Technical Manual iTNC 530 HSCI
The center offset is then automatically compensated during all probing
processes (see the User’s Manual):
With MP6160, select whether the spindle should be oriented in a 180°
rotation directly through the NC or through the PLC.
For spindle orientation by the NC you must reset M4012.
For spindle orientation by the PLC you must enter the number of the
M function in MP6160. The respective position is transferred as in the
"oriented spindle stop" cycle.
In the Manual Operation and Electronic Handwheel operating modes, the
rotation is activated after a soft key is pressed.
Special case: tilting axes
The actual position of the spindle position encoder can vary with tilted axes. It
depends on the machine’s mechanical design. Since the iTNC uses the actual
position of the spindle as its reference when compensating the eccentricity, it
would be necessary to recalibrate the touch probe for each new tilt in position:
In D760, enter the current offset with respect to the initial position.
Calibrate the touch probe in the initial position.
The iTNC compensates the entered offset when compensating the
eccentricity. In the initial position, D760 must equal 0.
MP6160 M function for probing from opposite orientations
Input: –1: Spindle orientation directly by NC
0: Function inactive
1 to 999: Number of the M function for spindle orientation by
the PLC
MP6180 Coordinates of the ring gauge center for Probing Cycle 2
with respect to the machine datum (traverse range 1)
Input: 0 to +99 999.9999 [mm]
MP6180.0 X coordinate
MP6180.1 Y coordinate
MP6180.2 Z coordinate
MP6181 Coordinates of the ring gauge center for Probing Cycle 2
with respect to the machine datum (traverse range 2)
Input: 0 to +99 999.9999 [mm]
MP6181.0 X coordinate
MP6181.1 Y coordinate
MP6181.2 Z coordinate
Set Reset
D760 Offset in tilting axes touch probe
center offset [1/10 000°]
PLC PLC
M4012 Open the spindle control loop PLC PLC