1578 HEIDENHAIN Technical Manual iTNC 530 HSCI
Module 9350 Read data from the tool table
Module 9350 reads the contents of a cell in the tool table with the status M.
The value is read as an integer value.
Call:
PS B/W/D/K <Tool number>
PS B/W/D/K <Tool index>
≤ 0: Main entry
PS B/W/D/K <Element number (see Module 9092)>
CM 9350
PL B/W/D <Element value>
PL B/W/D <Error number>
0: No error, element value was read
1: Module was not called in a spawn or submit job
2: File type does not exist
3: No tool table with status M
4: Line number does not exist
5: Incorrect element number
Error code:
Marker Value Meaning
M4203 0 Element value read
1 Error code in W1022
W1022 2 Incorrect element number
7 Line number does not exist
20 Module was not called in a spawn or submit job
36 No tool table with status M
41 Data type for the element is not supported