July 2013 8.15 Tool changer 1595
The current tool age is calculated in the Program Run, Single Block and
Program Run, Full Sequence operating modes if the following conditions are
fulfilled.
Spindle ON
No F MAX
F enable
Control-in-operation symbol is on
After program interruption with "internal stop," M02, M30 or END PGM, the tool
age counter is stopped.
The tool age counter does not run in the Manual Operation, Electronic
Handwheel and Positioning with MDI operating modes.
The user can reset the current tool age by entering zero.
MP7680 Machine parameter with multiple function
Input: Bit 6 – Tool length in blocks with normal vectors:
0: Without R2 from tool table (south pole)
1: With R2 from tool table (center of sphere)
MP7682 Machine parameter with multiple function
Input: Bit 14 – No insertion of the tool if TIME2 has expired
0: Tool is inserted even if TIME2 has expired
1: TOOL CALL for a tool where TIME2 has expired leads to an
error message and NC stop
Set Reset
M4543 Tool life 1 expired (TIME1 in the tool
table)
NC NC/PLC
M4546 Tool life 2 expired (TIME2 in the tool
table)
NC NC/PLC