1598 HEIDENHAIN Technical Manual iTNC 530 HSCI
Tool usage test for
pallet tables
The TOOL USAGE TEST soft key is also available for pallet tables.
If a line with an NC program is active, the test is performed only for the NC
program in question. The tool-usage file must first have been created in the
Test Run operating mode.
If a line with a pallet entry is active, the test is performed for the complete
pallet table. The tool-usage files of the NC programs called must first have
been created in the Test Run operating mode. One tool-usage file is created
for the entire pallet table.
With Module 9282, the tool-usage test for a pallet table can be performed
by the PLC. One tool-usage file is created for the entire pallet table.
Module 9282 Tool usage test for pallet table
Module 9282 allows you to check the tools used in a pallet table. The pallet file
must be selected in the Program Run, Single Block or Program Run, Full
Sequence operating mode. The tool usage file for the pallet table and the test
result file in ASCII format are created. The test result file contains the results
from the comparison of the tool usage file with the tool table.
If a pallet call is given as the line number, all subordinate machining operations
are checked. If a program call is given, only the tool usage file of the NC
program is checked.
Call:
PS B/W/D/K <Line number of the pallet table>
PS B/W/D/K/S<Name of the test result file (*.P.T.DEP)>
PS B/W/D/K/S<Name of the tool usage file (*.T.DEP)>
CM 9282
PL B/W/D <Result>
0: No error
1: Tool usage file of an NC program of the pallet table not
available or no longer up-to-date
2: Tool life not sufficient
3: Required tool not available
4: Radius of required tool is incorrect
5: Tool is not in magazine
6: Tool usage file of an NC program of pallet table cannot be
opened
7: Test result file could not be created
8: Test result file cannot be written to
9: Tool usage file of an NC program of pallet table cannot be
read
10: No memory for creating the tool usage file
Error code:
Marker Value Meaning
M4203 0 Tool usage test has been performed
1 Error code in W1022
W1022 11 Invalid string programmed
20 Module was not called in a spawn or submit job