July 2013 9.4 System Files 1705
PLCERRTAB = (Mandatory entry for PLC error messages): Path for PLC error message table.
If you compile a PLC program, the iTNC automatically enters it in the
OEM.SYS file.
Input example: PLCERRTAB = PLC:\ PLC_PGM \ERR_TAB.PET
PLCEVENTS = Path for event list (SPAWN command).
Input example: PLCEVENTS = PLC:\EVENTS.PEV
PLCMAIN = (Mandatory entry): Path for the active PLC program. If you compile a PLC
program, the iTNC automatically enters it in the OEM.SYS file.
Input example: PLCMAIN = PLC:\PLC_PGM\MAIN_530.PLC
PLCPASSWORD = Code number for calling the PLC mode (instead of 807667).
Input example: PLCPASSWORD = 123456789
PLCPWM = Path for PLC program for commissioning of digital axes
Input example: PLCPWM = PLC:\IB_PGM\IB530.PLC
PLCSOFTVERS = (Mandatory entry): iTNC displays PLC software version when the MOD key is
pressed.
Input example: PLCSOFTVERS = BASIS--33-03
PR.LINESLOCKED = Lines in the preset table that are to be write-protected, see page 1208.
Input example: PR.LINESLOCKED = 1,4-8,22
PWM
PARAMETER =
Number of the indexes of machine parameters MP2xxx.y (for the current and
speed controller) in the machine-parameter file (up to 30).
Input example: PWMPARAMETER = 6
REMOTE.
LOCKSOFTKEY
VISIBLE =
Display External access ON/OFF soft key.
Input example: REMOTE.LOCKSOFTKEYVISIBLE = YES
REMOTE.
PLCPASSWORD
FORCED =
Setup, machine backup and full backup only with the password from
PLCPASSWORD =
Input example: REMOTE.PLCPASSWORDFORCED = YES
REMOTE.
PLCPASSWORD
NEEDED =
Access to the PLC partition using the LSV2 protocol only with the password
from PLCPASSWORD =
Input example: REMOTE.PLCPASSWORDNEEDED = YES
Do not enter a code number that has already been defined by
HEIDENHAIN!