172 HEIDENHAIN Technical Manual iTNC 530 HSCI
2.7.9 HEROS 5 operating system
Boot manager A selection menu for selecting the operating mode is provided temporarily
when the control is booting. If you press one of the arrow keys of the ASCII
keyboard, the booting process is interrupted at this point and the control
expects you to select an operating mode ("runlevel"). If the booting process is
not interrupted at this point, the control continues booting in Runlevel 5 and
starts the NC control software. You can select one of the following operating
modes:
Runlevel 5: Start Control (standard mode of operation)
After the HEROS 5 operating system has booted, the NC control software
is started automatically. The iTNC 530 is started in the standard condition.
Runlevel 4: Service Mode (graphics)
This operating mode is only for trained service personnel!
After the HEROS 5 operating system has booted, the booting process is
stopped. The NC control software is not started. The iTNC 530 is now in the
graphic desktop of the operating system.
Runlevel 3: Service Mode (text)
This operating mode is only for trained service personnel!
After the HEROS 5 operating system has booted, the booting process is
stopped. The NC control software is not started. The iTNC 530 is in a text
console of the operating system.
Select the desired operating mode with the arrow keys and press the ENTER
key to start it.
HE Logging In controls with HSCI, the TRACE settings in MP7691.x are replaced by the
HE Logging settings. These are settings for internal diagnostic files (FILO
memory) for finding errors. These files can only be evaluated by HEIDENHAIN.
You can access HE Logging as follows if HEIDENHAIN service personnel
requests you to do so:
Make the taskbar at the bottom of the screen visible by moving the mouse
pointer over it.
Press the green HEIDENHAIN button to open the JH menu.
Select the Diagnostics menu item.
Select the HE Logging menu item.
This takes you to the HE Logging menu containing tabs for possible settings
for Syslog, FTrace and TCPDump. These possibilities for diagnostics and the
associated settings are to be used only together with HEIDENHAIN service
personnel.
Proceed as follows if HEIDENHAIN requests you to send one of the diagnosis
files:
Open the corresponding tab Syslog, FTrace or TCPDump.
Under View at the bottom of the respective tab, select the file requested by
HEIDENHAIN.
Press the Copy button to the right of the file selection in the View settings.
This opens the Savepath... file browser with which you can select the
target folder for the diagnostic file. Keep in mind that the file is saved in the
folder that is open in the file browser.