1864 HEIDENHAIN Technical Manual iTNC 530 HSCI
10.3 Connecting the iTNC to the Network
10.3.1 Settings at the iTNC
Press the MOD key in the Programming and Editing operating mode and
enter the code number NET123. Use the soft keys to select the required
network options:
The settings of the non-primary Ethernet interface(s), the selection of the
primary interface and the DHCP server settings are password protected. This
protects the settings from unauthorized changes. The code number 807667 or
the PLCPASSWORD defined in the OEM.SYS are required for these settings.
The code number is entered using the OEM authorization button or soft key.
Or you can open the network settings as follows:
Make the taskbar at the bottom of the screen visible by moving the mouse
pointer over it.
Press the green HEIDENHAIN button to open the JH menu.
Select the Settings menu item.
Select the Networks menu item.
Soft key Meaning
Settings on the iTNC 530 for networking. The network settings
for connecting the iTNC 530 to a network were completely
revised and are now divided into several pages of a window,
which can be selected by tabs.