If you want to design the control system in accordance with the new standard
ISO 13849-1, you need the corresponding validation values of the individual
control components for calculating the required performance level. This also
applies to the inverters and power supply modules used in a system with HSCI
but without integrated functional safety (FS). Only devices whose index or
version number is greater than or equal to the device version numbers listed
below in the right column are permitted for use in accordance with ISO 13849-
1. The devices listed in the middle column can also be used.
Below you will find an overview of the devices that—according to ISO 13849-
1—are permitted for use:
Device designation Device ID for systems
with integrated FS
Device ID for systems
without integrated FS
Inverter modules
UM 117DW 689572-01
UM 116D 667954-01 542998-01
UM 116DW 667946-01 369629-01 index B
UM 115D 671566-01 387852-01 index E
UM 114D 671288-01 510509-01 index E
UM 113D 730435-01 518703-01 index B
UM 112D 731984-01 519971-01 index C
UM 122D 667633-01 519972-01 index C
UM 121BD 667942-01 513037-01 index C
UM 111BD 671968-01 513035-01 index E
UM 121D 667838-01 392319-01 index F
UM 111D 667945-01 392318-01 index F
Power supply modules
UVR 120D 728252-01 390188-01 index K
UV 130D 728250-01 389311-01 index E
UVR 130D 728248-01 377639-01 index K
UVR 140D 728253-01 390281-01 index N
UVR 150D 728255-01 390421-01 index P
UVR 160D 728257-01 530341-01 index G
UVR 160DW 728258-01 560106-01 index G
UVR 170DW 546911-02
UVR 170D 807429-01