EasyManua.ls Logo

HEIDENHAIN iTNC 530 HSCI - X90: +24 V NC Output of the Uxc 11 X (FS)

HEIDENHAIN iTNC 530 HSCI
1966 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
230 HEIDENHAIN Technical Manual iTNC 530 HSCI
3.8.3 X90: +24 V NC output of the UxC 11x (FS)
Assignment
Load capacity
Current
consumption of the
HSCI components
Example: Typical TNC 620 configuration with UEC 11x
A PSL 130 unit is not needed for this application. The +24 V NC supply of the
UEC 11x (X90) suffices for the connected components.
Connecting
terminal X90
Assignment
+ or terminal 1 +24 V NC (max. 3.5 A)
– or terminal 2 0 V
Attention
The interface is electrically separated (protective extra-low voltage (PELV)
as per EN 61800-5-1).
Device Load capacity of 24 V NC supply (X90)
UEC 11x (FS) 3.5 A
Device Current consumption of the 24 V NC
supply
MC 6110 or MC 7110 1.8 A
MB 620 or MB 720
(including all PLC outputs)
1.0 A
PL 62xx
(incl. TS and TT)
0.5 A
PL 61xx 0.2 A
Device Current consumption 24 V
NC
MC 6110 or MC 7110 1.8 A
MB 620 or MB 720 (including all PLC
outputs)
1.0 A
PL 61xx 0.2 A
Total 3.0 A < 3.5 A