234 HEIDENHAIN Technical Manual iTNC 530 HSCI
However, if you want to arrange two CC 61xx controller units other than the
CC 6106 controller unit next to each other in one row, you need to use the
ribbon cable with ID 325 816-22. This cable is required for the following
configurations: 2 x CC 6108, 2 x CC 6110 or CC 6110 with CC 6108. The four
connectors X69 of the CCs are then connected via the additional accessory
cable. The fifth connector of the cable is used to establish the connection to
X69 of the power supply module.
If several CC 61xx controller units are connected via a cable with ID 325 816-
xx, the +5 V power must usually only be supplied by connector X74 of the
rightmost CC controller unit. This +5 V supply must be tested.
Ribbon cable
ID 325 816-24 on
two CC 6106
controller units
ID 325 816-22
on two CC 6108
controller units