EasyManua.ls Logo

HEIDENHAIN iTNC 530 HSCI - Page 259

HEIDENHAIN iTNC 530 HSCI
1966 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
July 2013 3.10 UxC 11x (FS): Power supply and motor connection 259
With a power supply of 400 V, the inverter voltage U
Z
is 565 V–, and with a
power supply of 480 V it is 678 V–.
For information on the power connection, refer to the Technical Manual for
"Inverter Systems and Motors."
Connecting
terminals
UEC 111, UEC 112
Operation on 400 V~
L1 400 V~ ± 10 %
50 Hz to 60 Hz
L2
L3
Cable / single conductor (HT wire):
6 mm
2
(AWG 10)
Single conductor H07 V2-K:
4 mm
2
(AWG 10)
Line fuse:
25 A (gR) Siemens Sitor type
Grounding terminal:
10 mm
2
(AWG 6)
Tightening torque for connecting terminals:
0.7 Nm (6.5 to 7 pound-inch)
Operation on 480 V~
L1 480 V~ ± 10 %
50 Hz to 60 Hz
L2
L3
Cable / single conductor (HT wire):
6 mm
2
(AWG 10)
Single conductor H07 V2-K:
4 mm
2
(AWG 10)
Line fuse:
25 A (gR) Siemens Sitor type
Grounding terminal:
10 mm
2
(AWG 6)
Tightening torque for connecting terminals:
0.7 Nm (6.5 to 7 pound-inch)