EasyManua.ls Logo

HEIDENHAIN iTNC 530 HSCI - Page 286

HEIDENHAIN iTNC 530 HSCI
1966 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
286 HEIDENHAIN Technical Manual iTNC 530 HSCI
Terminals on the
PLA-H 08-04-04
Power consumption of a PLA-H 08-04-04 I/O module:
Without load: 2.6 W
Under full load: 4.5 W
X46 to X49:
Analog inputs
Pin layout
Properties Socket connectors on the PLA-H 08-04-04
Connection: Socket connector with tension clamp
connection, type:
X81, X82:
Weidmüller B2L 3.5/10 SN SW
2-row, 10-pin
X66, X67, X46, X47, X48, X49:
Weidmüller B2L 3.5/6 SN SW
2-row, 6-pin
Connectable conductors: Usable conductor cross sections without
wire-end sleeve:
0.08 mm
2
to 1.0 mm
2
Usable conductor cross sections with wire-
end sleeve:
0.14 mm
2
0.34 mm
2
0.5 mm
2
(only with Weidmüller PZ 6/5
crimping pliers)
Note
HEIDENHAIN recommends:
Preferably use a conductor cross section of 0.34 mm
2
if you use stranded
wires with wire-end sleeves. This cross section can be clamped
appropriately and ensures a reliable terminal connection.
If you use stranded wires with wire-end sleeves and a conductor cross
section of 0.5 mm
2
, the Weidmüller PZ 6/5 crimping pliers (setting 0.25–0.5
mm
2
) must be used for crimping. In this case, orient the crimped wire-end
sleeve before inserting it into the socket connector. If crimping pliers from
other manufacturers are used for crimping conductors with a cross section
of 0.5 mm
2
, the crimped wire-end sleeves cannot be inserted into the
socket connector and clamped appropriately, and therefore do not result in
a reliable terminal connection.
Connecting terminals Assignment
1a/1b –10 V to +10 V (input)
2a/2b 0 V (reference potential)
3a/3b Shield

Table of Contents