July 2013 3.22 Encoder connections 299
X201 to X206:
Position encoder
with EnDat 2.2
interface
Pin layout:
CC 6106 Adapter cable 673459-xx
Male Assignment Female Color Female
1+5 V (U
P
)1
Brown/
Green 11
20 V (U
N
)2
White/
Green 12
3 A+ 3 Vacant
4 A– 4 Vacant
5 Data 5 Gray 2
6 B+ 6 Vacant
7 B– 7 Vacant
8 Data
8Pink1
9
+5 V (sensor)
9Blue14
10 Vacant 10 Vacant
11
0 V (sensor)
11 White 13
12 Vacant 12 Vacant
13
Internal shield
13 Vacant
14 Clock 14 Violet 10
15 Clock
15 Yellow 9
Hsg. Housing Hsg.
External
shield Hsg.
Note
The interface complies with the requirements of EN 50178 for "low voltage
electrical separation."