EasyManua.ls Logo

HEIDENHAIN iTNC 530 HSCI - CMA-H 04-04-00-Pin Layout

HEIDENHAIN iTNC 530 HSCI
1966 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
310 HEIDENHAIN Technical Manual iTNC 530 HSCI
3.25.1 CMA-H 04-04-00—Pin layout
CMA-H
Analog outputs
X67: Analog outputs 3 and 4
X66: Analog outputs 1 and 2
X47: Reserved, do not assign
X46: Reserved, do not assign
X67
X66
X47
X46
1
2
3
1
2
3
a
b
1
2
3
1
2
3
X66: Analog outputs 1 and 2
Function Analog output 1
Connecting terminal 1a 2a 3a
Assignment ±10 V 0 V Shield
Function Analog output 2
Connecting terminal 1b 2b 3b
Assignment ±10 V 0 V Shield
X67: Analog outputs 3 and 4
Function Analog output 3
Connecting terminal 1a 2a 3a
Assignment ±10 V 0 V Shield
Function Analog output 4
Connecting terminal 1b 2b 3b
Assignment ±10 V 0 V Shield
Note
The terminals X46 and X47 on the CMA-H 04-04-00 are reserved for future
functions and are not yet supported by the NC software. Please do not
assign them.