354 HEIDENHAIN Technical Manual iTNC 530 HSCI
0 V PLC must be connected to terminal 1.
X111 to X113:
Potentiometer
connection
Pin layout:
X168: PLC inputs, channel B
Assignment Terminal
1 2 3 4 5 6 7 8 9
PLB 6001 FS 0 V
PLC
I24.B I25.B I26.B I27.B I28.B I29.B I30.B I31.B
Connecting
terminals
Assignment
1 0 V potentiometer
2 Potentiometer arm
3 +5 V potentiometer