EasyManua.ls Logo

HEIDENHAIN iTNC 530 HSCI - Itnc 530 HSCI Cable Overview-Basic Configuration, MC in Operating Panel, UEC 1 Xx

HEIDENHAIN iTNC 530 HSCI
1966 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
July 2013 3.51 iTNC 530 HSCI cable overview—Basic configuration, MC in operating panel, UEC 1xx 472
3.51 iTNC 530 HSCI cable overview—Basic configuration, MC in operating panel, UEC 1xx
UEC 11x
X201 ... X204 (UEC 111)
X502
X500
PLC I/O
X201 ... X205 (UEC 112)
X15 ... X18 (UEC 111)
X15 ... X19 (UEC 112)
12m
60m
309 783-xx
310 199-xx
336 376-xx
60m
336 376-xx
LC x83
KTY
533
631-xx max. 6m
340 302-xx
289 440-xx
KTY
LB/LS
60m
max. 9m
289 440-xx
VL
336 847-xx
60m
VL
323 897-xx
509 667-xx
1)
1m
RCN 729
RCN 226
RCN 228
2)
X500
HSCI
PL 610x
2)
1)
X80 ... X84
X501
USB
X502
X502
HSCI
HSCI
X502
722 414-xx
M12
688 144-xx
HSCI
HSCI
360 974-xx (LS x87)
298 429-xx (LB, LF 183)
298 430-xx (LF 481)
max. 20m
max. 12m
max. 12m
558 714-xx max. 30m
332 115-xx
LC
LC x83
60m
VL
323 897-xx
LC x83
RCN 729
RCN 226
RCN 228
533
631-xx max. 9m
1m
30m
673 459-xx max. 20m
533 627-xx
368 330-xx
533
661-xx max. 16m
3)
4)
3)
4)
3)
4)
3)
4)
3)
4)
X500
MC 7222
MC 6222
TE 735 /TE 745
TE 635Q
TE 720/TE 730
TE 620/ TE 630
MB 720
MB 620
12.04.2012
USB 2.0 354 770-xx
USB 1.1 624 775-xx
max. 5m
max. 20m
X10
X10
633 299-04
X1 X3
X1
1 V
PP
Position inputs
1 V
PP
1 V
PP
Speed inputs
EnDat 2.1 interface
Axes + spindle:
Axes: 60m
Voltage controller 5 V
368 210-01
Voltage controller 5 V
383 951-01
1 V
PP
1 V
PP
only for connection of the KTY
Adapter connector 544 703-01
for spindle (if necessary)
Cabinet
VL: Extension cable
 for separation points with connecting cable
 for extending existing connecting cable
*) included with the MC (1,5m)
**) included with the MB (0,5m)
HSCI total length 70 m
Bold (e.g. MC 7222) Design 7,
available as of mid-2012
Normal (e.g. MC 6222) Design 6
EnDat with incremental signals
Pure serial EnDat 2.2
ribbon cable for pots
ribbon cable for sk
ribbon cable for sk
*)
**)
*)
40 inputs
24 outputs
Please note that the cable overviews already contain components in the new design (Design 7).

Table of Contents

Other manuals for HEIDENHAIN iTNC 530 HSCI

Related product manuals