July 2013 4.3 Input and output of machine parameters 481
Manual input Call the machine parameter editor through the MOD function "code
number":
By entering the code number 95148 you gain access to the complete list
of machine parameters.
By entering the code number 123 you gain access to a subset of machine
parameters. This subset can be changed by the user (see the User’s
Manual). Machine parameters that can be accessed through the code
number 123 are indicated in the list with the symbol CN123.
To exit the machine parameter editor, press the END key.
User parameters You can access some machine parameters without first entering a code
number.
In MP7330.x, define up to 16 machine parameters and define the associated
dialog in MP7340.x. The dialog is shown whenever the USER PARAMETERS
soft key is pressed (up to 37 characters).
Select the MOD function USER PARAMETER.
Protecting the
machine parameter
list
To protect the current machine parameter list from being edited through the
code number 95148:
In the OEM.SYS file, define a new code number in the entry MPPASSWORD =
for editing the machine parameter list. Then it is no longer possible to edit
through the code number 95148.
To protect individual machine parameters against editing:
In the MPLOCKFILE = entry in the OEM.SYS file, enter the path of a machine-
parameter subfile. Then it is only possible to edit those machine parameters
that have no value assigned in this file. If there is a difference between the
current MP value and the MP value in this subfile, the control displays an
error message and a window offering the value from the subfile for your
acceptance.