494 HEIDENHAIN Technical Manual iTNC 530 HSCI
4.4 List of machine parameters
4.4.1 Encoders and machines
MP Function and input Software
version and
behavior
Page
MP10 Active axes
Format: %xxxxxxxxxxxxxxxxxx
Input: Bits 0 to 17 represent axes 1 to 18
0: Axis not active
1: Axis active
PLC
RUN
603
MP12 Axis-specific demo operation for NC axes
Format: %xxxxxxxxxxxxxxxxxx
Input: Bits 0 to 17 represent axes 1 to 18
0: Demo operation not active
1: Demo operation active
PLC
RUN
604
MP20 Monitoring functions for the axes
Format: %xxxxxxxxxxxxxxxxxx
Input: Bits 0 to 17 represent axes 1 to 18
0: Monitoring not active
1: Monitoring active
PLC
RUN
610
MP20.0 Absolute position of the distance-coded reference marks
MP20.1 Amplitude of encoder signals
MP20.2 Edge separation of encoder signals
MP21 Monitoring functions for the spindle
Format: %xx
Input: Bit 0 – Spindle 1
0: Monitoring not active
1: Monitoring active
Bit 1 – Spindle 2
0: Monitoring not active
1: Monitoring active
PLC
RUN
610
MP21.0 Absolute position of the distance-coded reference marks
MP21.1 Amplitude of encoder signals
MP21.2 Edge separation of encoder signals
MP100 Designation of axes
Format: -wvucbazyxWVUCBAZYX
Any lowercase letters for auxiliary axes,
any uppercase letters for slave axes
Input: Characters 1 to 9 from the right represent
axes 1 to 18
PLC
RUN
603,
630
MP100.0 Traverse range 1
MP100.1 Traverse range 2
MP100.2 Traverse range 3