500 HEIDENHAIN Technical Manual iTNC 530 HSCI
MP850.x Synchronized axes
Input: 0: Master axis
1: Slave axis to axis 1
2: Slave axis to axis 2
3: Slave axis to axis 3
4: Slave axis to axis 4
5: Slave axis to axis 5
6: Slave axis to axis 6
7: Slave axis to axis 7
8: Slave axis to axis 8
9: Slave axis to axis 9
10: Slave axis to axis 10
11: Slave axis to axis 11
12: Slave axis to axis 12
13: Slave axis to axis 13
14: Slave axis to axis 14
15: Slave axis to axis 15
16: Slave axis to axis 16
17: Slave axis to axis 17
PLC
RUN
779
MP855.x Synchronization monitoring
Input: 0 to 100.0000 [mm]
0: Monitoring not active
PLC
RUN
781
MP860.x Datum for synchronous control
Format: %xxx
Input: Bit 0 – Datum position for synchronous control
0: Datum at position after switch-on
1: Datum at reference marks (machine datum)
Bit 1 – Master-slave torque control
0: Axis is not slave axis in master-slave torque control
1: Axis is slave axis in master-slave torque control
Bit 2 – Brake test of slave axis
0: Test the brakes of a synchronized axis simultaneously
1: Test the brakes of a synchronized axis successively
PLC
RUN
781,
785
MP910.x Positive software limit switches, traverse range 1 (default
setting after power on)
Input: –99 999.9999 to +99 999.9999 [mm] or [°]
PLC
RUN
628
MP911.x Positive software limit switches, traverse range 2
Input: –99 999.9999 to +99 999.9999 [mm] or [°]
PLC
RUN
628
MP912.x Positive software limit switches, traverse range 3
Input: –99 999.9999 to +99 999.9999 [mm] or [°]
PLC
RUN
628
MP Function and input Software
version and
behavior
Page