502 HEIDENHAIN Technical Manual iTNC 530 HSCI
4.4.2 Positioning
MP Function and input Software
version and
behavior
Page
MP1010.x Rapid traverse
Input: 10 to 1 000 000 [mm/min or °/ min]
PLC
RUN
842
MP1011 Limit of rapid traverse on the path
Input: 10 to 1 000 000 [mm/min or °/ min]
PLC
RUN
842
MP1012.x Second axis-specific rapid traverse
Input: 10 to 1 000 000 [mm/min or °/ min]
842
MP1020.x Manual feed
Input: 10 to 300 000 [mm/min]
PLC
RUN
842
MP1030.x Positioning window
Input: 0.0001 to 2.0000 [mm] or [1000°/s2]
PLC
RUN
900
MP1040 Analog axes: Polarity of nominal value voltage
Digital axes: Algebraic sign of the nominal speed value
Format: %xxxxxxxxxxxxxxxxxx
Input: Bit 0 to Bit 17 represent axis 1 to 18
0: Positive
1: Negative
609
MP1050.x Analog axes: Analog voltage at rapid traverse
Input: 1.000 to 9.000 [V]
Digital axes: without function
Input: 1
PLC
RUN
842
MP1054.x Distance of one motor revolution [mm or °]
Input: Analog axes: Without function
Digital axes: Entry of a formula possible, *** "Special case:
Entering a formula" on page 479 ***
PLC
RUN
899
MP1060.x Acceleration
Input: 0.001 to 500 [m/s
2
] or [1000°/s
2
]
PLC
RUN
818
MP1061 Limitation of the path acceleration
Input: 0.001 to 500 [m/s
2
] or [1000°/s
2
]
PLC
RUN
818
MP1061.0 For machining feed rate
MP1061.1 For rapid traverse
MP1070 Radial acceleration
Input: 0.001 to 500 [m/s
2
]
PLC
RUN
891
MP1080.x Analog axes: Integral factor for offset adjustment
Input: Enter 0 to 65 535
Digital axes: No function
Input: 0
PLC
RUN
890