EasyManua.ls Logo

HEIDENHAIN iTNC 530 HSCI - Positioning

HEIDENHAIN iTNC 530 HSCI
1966 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
502 HEIDENHAIN Technical Manual iTNC 530 HSCI
4.4.2 Positioning
MP Function and input Software
version and
behavior
Page
MP1010.x Rapid traverse
Input: 10 to 1 000 000 [mm/min or °/ min]
PLC
RUN
842
MP1011 Limit of rapid traverse on the path
Input: 10 to 1 000 000 [mm/min or °/ min]
PLC
RUN
842
MP1012.x Second axis-specific rapid traverse
Input: 10 to 1 000 000 [mm/min or °/ min]
842
MP1020.x Manual feed
Input: 10 to 300 000 [mm/min]
PLC
RUN
842
MP1030.x Positioning window
Input: 0.0001 to 2.0000 [mm] or [1000°/s2]
PLC
RUN
900
MP1040 Analog axes: Polarity of nominal value voltage
Digital axes: Algebraic sign of the nominal speed value
Format: %xxxxxxxxxxxxxxxxxx
Input: Bit 0 to Bit 17 represent axis 1 to 18
0: Positive
1: Negative
609
MP1050.x Analog axes: Analog voltage at rapid traverse
Input: 1.000 to 9.000 [V]
Digital axes: without function
Input: 1
PLC
RUN
842
MP1054.x Distance of one motor revolution [mm or °]
Input: Analog axes: Without function
Digital axes: Entry of a formula possible, *** "Special case:
Entering a formula" on page 479 ***
PLC
RUN
899
MP1060.x Acceleration
Input: 0.001 to 500 [m/s
2
] or [1000°/s
2
]
PLC
RUN
818
MP1061 Limitation of the path acceleration
Input: 0.001 to 500 [m/s
2
] or [1000°/s
2
]
PLC
RUN
818
MP1061.0 For machining feed rate
MP1061.1 For rapid traverse
MP1070 Radial acceleration
Input: 0.001 to 500 [m/s
2
]
PLC
RUN
891
MP1080.x Analog axes: Integral factor for offset adjustment
Input: Enter 0 to 65 535
Digital axes: No function
Input: 0
PLC
RUN
890