516 HEIDENHAIN Technical Manual iTNC 530 HSCI
MP2220.x Monitoring functions
Format: %xxxxxxxxxxxxxxxx
Input: Bit 0 – Monitoring the reference mark
0: Monitoring active
1: Monitoring inactive
Bit 1 – Monitoring the direction of rotation
0: Monitoring active
1: Monitoring inactive
Bit 2 – Power limit of spindle with ERR.IZ.GR
(only for
HEIDENHAIN inverters, except UE 2xx)
0: Power limit active
1: Power limit inactive
(All HEIDENHAIN inverters except UE 2xx)
Bit 3 – Switching off the controller when the motor brakes
are activated
0: Suppress oscillations
1: Oscillations are allowed
PLC
RUN
875;
925,
951,
1087
Bit 4 – Monitoring for excessive temperature
0: Active
1: Inactive
Bit 5 – Monitoring for insufficient temperature
0: Active
1: Inactive
Bit 6 – Reserved
Bit 7 – Monitoring of encoder input frequency
0: Active
1: Inactive
Bit 8 – Adjust mechanical offset by gradually increasing the
k
V
factor
0: Active
1: Inactive
Bits 9 to 15 – Reserved
MP2221.x Special motor functions
Format: %xxxxxxxxxxxxxxxx
Input:
Bit 7 – Switch-on time of the drive
0: Reduction of the switch-on time is active
1: Reduction of the switch-on time is not active
Bit 10 – Handling of linear and synchronous motors to attain
higher milling power with AFC
0: Handling for attaining higher milling power is active
1: Handling for attaining higher milling power is not active
PLC
RUN
863
1233
MP Function and input Software
version and
behavior
Page