526 HEIDENHAIN Technical Manual iTNC 530 HSCI
4.4.6 Spindle
MP Function and input Software
version and
behavior
Page
MP3010 Output of speed, gear range
Input: 0: No output of spindle speed
1: Speed code if the speed changes
2: Speed code at every TOOL CALL
3: Nominal speed value always, G code if the gear range
shifts
4: Nominal speed value always, G code at every TOOL
CALL
5: Nominal speed value always, no G code
6: Same as 3, but with controlled spindle for orientation
7: Same as 4, but with controlled spindle for orientation
8: Same as 5, but with controlled spindle for orientation
PLC
RUN
944
MP3011 Function of analog output S, if MP3010 < 3
Input: 0: No special function
1: Voltage is proportional to the current contouring feed
rate, depending on MP3012
2: Voltage is defined as through Module 9130
3: Voltage is defined through M functions (M200 to M204)
1561
MP3012 Feed rate from output of an analog voltage of 10 V,
MP3011 = 1
Input: 0 to 300 000 [mm/min]
1561
MP3013.x Characteristic curve kink points (velocity) for output of the
analog voltage with M202
Input: 10 to 300 000 [mm/min]
PLC
RUN
1562
MP3014.x Characteristic curve kink points (voltage) for output of the
analog voltage with M202
Input: 0.000 to 9.999 [V]
PLC
RUN
1562
MP3020 Speed range for S code output
Format: xxyyz
xx: S code for minimum speed
yy: S code for maximum speed
z: Speed increment
Input: 0 to 99 999
PLC
RUN
965
MP3030 Behavior of the spindle
Input: Bit 0 –
0: Axis stop for TOOL CALL S
1: No axis stop for TOOL CALL S
Bit 1: Zero spindle speed when switching to another gear
range
0: Reduce speed to 0
1: Do not reduce speed to 0
PLC
RUN
960,
1564