MP6165 Orient the probe before approaching with Cycle 0 or 1, or
with manual probing
Input: 0: Probe is not oriented before each probing
1: Probe is oriented and always deflected in the same
direction
PLC
RUN
CN123
1540
MP6166 Probing direction of the touch probe with consideration of
an active basic rotation (only manual measuring cycles)
Input: 0: Inactive
1: Active
PLC
RUN
CN123
1540
MP6170 Number of measurements in a programmed measurement
(touch probe block)
Input: 1 to 3
PLC
RUN
CN123
1545
MP6171 Confidence range for programmed measurement
(MP6170 > 1)
Input: 0.002 to 0.999 [mm]
PLC
RUN
CN123
1545
MP6180 Coordinates of the ring gauge center for automatic
calibration (Probing Cycle 2) with respect to the machine
datum (traverse range 1)
Input: 0 to +99 999.9999 [mm]
PLC
CN123
1544
MP6180.0 X coordinate
MP6180.1 Y coordinate
MP6180.2 Z coordinate
MP6181 Coordinates of the ring gauge center for automatic
calibration (Probing Cycle 2) with respect to the machine
datum (traverse range 2)
Input: 0 to +99 999.9999 [mm]
PLC
CN123
1544
MP6181.0 X coordinate
MP6181.1 Y coordinate
MP6181.2 Z coordinate
MP6182 Coordinate of the ring gauge center for Probing Cycle 2 with
respect to the machine datum (traverse range 3)
Input: 0 to +99 999.9999 [mm]
PLC
CN123
1545
MP6182.0 X coordinate
MP6182.1 Y coordinate
MP6182.2 Z coordinate
MP6185 Distance of probing point below ring top surface during
calibration
Input: +0.001 to +99 999.9999 [mm]
PLC
CN123
1545
MP Function and input Software