546 HEIDENHAIN Technical Manual iTNC 530 HSCI
MP7260 Number of tools in the tool table
MP7260 can also be overwritten by the PLC and the LSV2
protocol.
Input: 0 to 30 000
CN123 1567
MP7261.0-15 Number of pockets in the tool magazine 1 to 16
MP7261 can also be overwritten by the PLC and the LSV2
protocol.
Input: 0 to 9999
CN123 1567
MP7262 Maximum tool index number for indexed tools
MP7262 can also be overwritten by the PLC and the LSV2
protocol.
Input: 0 to 9
CN123 1596
MP7263 Pocket table
MP7263 can also be overwritten by the PLC and the LSV2
protocol.
Format: %xxxxxxx
Input: Bit 0 –
0: Show POCKET TABLE soft key
1: Hide POCKET TABLE soft key
Bit 1 – Output of the columns for file functions
0: Output only the displayed columns
1: Output all columns
Bit 2 – Show the "Edit ON/OFF" soft key in the pocket table
0: Display soft key
1: Do not display soft key
Bit 3 – Soft keys "Reset pocket table" and "Reset column T"
0: Display soft keys
1: Do not display soft keys
Bit 4 - Deletion possible for a tool that is in the pocket table.
Deletion must be confirmed.
0: Deletion impossible
1: Deletion possible (with confirmation)
Bit 5 – Deletion of a tool possible even without confirmation
(if bit #4 = 1)
0: Deletion not possible without confirmation
1: Deletion possible without confirmation
Bit 6 – Deletion of index entries of a tool behaves like
deletion of a tool. The settings of bits 4 and 5
also apply to the index entries if bit 6 is set.
0: Deletion always impossible
1: Deletion possible depending on settings in bits 4 and 5
CN123 1567
MP Function and input Software
version and
behavior
Page