550 HEIDENHAIN Technical Manual iTNC 530 HSCI
MP7294 Disable axis-specific "Datum setting" in the preset table
Format: %xxxxxxxxxxxxxxxxxx
Input: Bits 0 to 17 represent axes 1 to 18
0: Not disabled
1: Disabled
PLC
RUN
CN123
1209
MP7295 Disable "Datum setting"
Format: %xxxxxxxxxxxxxxxxxx
Input: Bits 0 to 17 represent axes 1 to 18
0: Not disabled
1: Disabled
PLC
RUN
CN123
1207
MP7296 "Datum setting" through axis keys
Input: 0: Datum can be set by axis keys and soft key
1: Datum can be set only by soft key
PLC
RUN
CN123
1207
MP7300 Erasing the status information, tool data and Q parameters
Input: 0: Erase the status information, Q parameters
and tool data if a program is selected.
1: Erase the status information, Q parameters and tool data
if a program is selected and in the event of M02,
M30, and END PGM.
2: Erase the status information and tool data if a program is
selected.
3: Erase the status information and tool data if a program is
selected and in the event of M02, M30, END
PGM.
4: Erase the status information and Q parameters if a
program is selected.
5: Erase the status information and Q parameters if a
program is selected and in the event of M02,
M30, END PGM.
6: Erase the status information if a program is selected and
in the event of M02, M30, END PGM.
7: Erase the status information if a program is selected and
in the event of M02, M30, END PGM.
PLC
RUN
CN123
1161
MP Function and input Software