592 HEIDENHAIN Technical Manual iTNC 530 HSCI
M 4040 Status display M07, M08, and M09
highlighted
PLC PLC 1157
M 4041 Status display M07, M08, M09, MK PLC PLC 1157
M 4042 Status display M07, M08, M09, MK PLC PLC 1157
M 4050 Touch probe not ready (ready signal is
missing)
NC NC 1537
M 4051 Stylus deflected before start of probing
cycle
NC NC 1537
M 4052 Stylus is deflected, probing process is
completed
NC PLC 1537
M 4053 Probing process has been completed or
canceled
NC NC 1537
M 4054 Battery voltage too low (battery warning at
touch probe connection); evaluated only
during the probing process
NC NC 1537
M 4055 Enable the probing process NC PLC 1537
M 4056 NC stop in all operating modes if stylus is
deflected
PLC PLC 1537
M 4057 Touch probe cycle active (FN17: ID990
NR2)
NC NC –
M 4060 Cycle for tool measurement started NC NC 1560
M 4061 0: Measure the tool
1: Check the tool
NC NC 1560
M 4062 0: Wear tolerance not exceeded
1: Wear tolerance exceeded
NC NC/
PLC
1560
M 4063 0: Breakage tolerance not exceeded
1: Breakage tolerance exceeded
NC NC/
PLC
1560
M 4065 Workpiece dimensions are OK NC PLC 1545
M 4066 Workpiece must be reworked NC PLC 1545
M 4067 Workpiece is scrap NC PLC 1545
M 4070 Strobe signal for gear code NC NC 960
M 4071 Strobe signal for S code NC NC 965
M 4072 Strobe signal for M function NC NC 1254
M 4073 Strobe signal T code (P code) with
TOOL CALL
NC NC 1611,
1629
M 4074 Strobe signal T code (P code) with
TOOL DEF
NC NC 1611,
1629
M 4075 Transfer active with FN19 NC NC 1713
M 4090 Acknowledgment of "gear change
completed"
PLC PLC 960
M 4091 Acknowledgment of S code PLC PLC 965
M 4092 Acknowledgment of M function PLC PLC 1254
Operand Description Set Reset SW version Page