64 HEIDENHAIN Technical Manual iTNC 530 HSCI
Module 9286 Select the VNC client and control the focus assignment
PLC Module 9286 is used to program the following status requests regarding
the control and assignment of multiple VNC clients:
Select the active VNC client and simultaneously the assignment of the focus
Enable or disable focus assignment (mouse operation, touchpad) for the
user
Constraints:
Call only from a submit/spawn job
The names of the VNC clients (host name or MAC address) can be
ascertained with Module 9287
Call:
PS B/W/D/K <Mode>
0: Define the active VNC client and simultaneously assign
the focus
1: Enable or disable focus assignment
PS B/W/D/K <Name>
Mode 0: PLC string with host name or IP address
Mode 1: - - -
PS B/W/D/K <Timeout [ms]>
Module rounds up to the next 100 ms limit
0: Default timeout 3000 ms
PS B/W/D/K <Additional parameter>
Mode 0:
0: Enable focus assignment
1: Disable focus assignment
2: Focus assignment unchanged
Mode 1:
0: Enable focus assignment
1: Disable focus assignment
CM 9286
PL B/W/D <Error code>
0: No error
1: PLC error, error code in PLC error word (see below)
>= 100: Operating-system error