April 2013 1.9 PLC functions 69
Error code:
Marker Value Meaning
M4203 0 No error
1 Faulty execution of module
W1022 1 Mode parameter is invalid
2 Timeout parameter or additional parameter parameter
is invalid
3 Parameter name is invalid
20 Call was not in a submit/spawn job
45 PLC module cancelled (operating-system error)
51 NC software does not support module
61 Function could not be executed
100 Invalid parameter
110 Focus assignment unclear, currently no master
111 Client could not be set as master
120, 121,
122
Disabling of focus assignment not supported
130 Unknown status of focus assignment
131, 132,
133, 134
Interference in communication for focus assignment
200, 201 Internal error