710 HEIDENHAIN Technical Manual iTNC 530 HSCI
Step 2a
Determining the Z offset:
Deactivate 3-D ROT
Position A = –90
Set the dial gauge to 0
Set display Z = 0
Step 2b
Determining the Z offset:
Position A = 0
Move the Z axis until the dial
gauge reads 0 at the spindle
tip
<Line no. [0] Column
COORD> = "determined value" –
cylinder radius