732 HEIDENHAIN Technical Manual iTNC 530 HSCI
Module 9097 Select the geometry description
A geometry description from an assignment table can be chosen with Module
9097. The module can be called in a running NC program only in connection
with a strobe. The module must be called in a submit job or spawn job, and
cannot be canceled with the CAN command.
Call:
PS B/W/D/K <Line number in the assignment table>
PS B/W/D/K <Mode, reserved>
Transferred value must be 0
CM 9097
PL B/W/D <Error condition>
0 = Geometry description was selected
1 = Invalid mode
2 = Line was not found in the assignment table
3 = Assignment table is not defined
4 = Description table does not exist
5 = Description table is incomplete
6 = Module was not called in a spawn job or
submit job
7 = Call during running NC program without strobe
8 = No KINEMATIC= entry in the OEM.SYS file
9 = Error in the MPFILE column
10 = Error in the MP7500 column
11 = Error in the machine parameter subfile
12 = Reserved
13 = Names of collision objects (CMO) not unique
Error code:
Marker Value Meaning
M4203 0 Geometry description was selected
1 Error code in W1022
W1022 2 Invalid mode; or line was not found in the assignment
table; or description table was not defined, does not
exist or is incomplete; or there is no KINEMATIC=
entry in the OEM.SYS file.
9 Error in the MPFILE column
10 Error in the MP7500 column
11 Error in the machine parameter subfile
20 Module was not called in a submit or spawn job
21 Call was made during a running NC program without a
strobe