818 HEIDENHAIN Technical Manual iTNC 530 HSCI
MP1060.x Acceleration
Input: 0.001 to 500 [m/s
2
] or [1000°/s2]
MP1061.0 Limitation of the path acceleration for machining feed rate
Input: 0.001 to 500 [m/s
2
] or [1000°/s2]
MP1061.1 Limitation of the path acceleration for rapid traverse
Input: 0.001 to 500 [m/s
2
] or [1000°/s2]
MP1085.x Axis-specific jerk for path movements in the operating
modes Program Run Full Sequence, Program Run Single
Block, and Positioning with Manual Data Input
Input: 0.0 to 9999.9 [m/s
3
or
1000° /s
3
]
MP1086.x Maximum permissible jerk during single-axis movements
at rapid traverse for the operating modes Program Run Full
Sequence, Program Run Single Block, and Positioning with
Manual Data Input
Input: 0: Function inactive
0.0 to 9999.9 [m/s
3
or 1000° /s
3
]
MP1087.x Maximum permissible axis-specific jerk for Manual
operating mode
Input: 0.1 to 1000.0 [m/s
3
or 1000°/s
3
]
MP1088.x Axis-specific jerk limiting for unfiltered positioning
movements
Input: 0.1 to 9999.9 [m/s
3
or 1000° /s
3
]
MP1089.x Max. permissible axis-specific jerk for Pass Over Reference
Point mode
Input: 0.1 to 1000.0 [m/s
3
or 1000°/s
3
]
MP1090.x Maximum permissible jerk on the tool path
Input: 0.0 to 9999.9 [m/s
3
or 1000° /s
3
]
0: Not active
MP1090.0 With machining feed rate
MP1090.1 Beginning with feed rate from MP1092
MP1092 Feed rate threshold for jerk parameters from MP1085.x and
MP1086.x
Input: 1 to 300 000 [mm/min]
0: Not active
MP1521 Transient response during acceleration and deceleration
Input: 1 to 255 [ms]
0: Function inactive