EasyManua.ls Logo

HEIDENHAIN iTNC 530 HSCI - List of the Nominal Position Value Filters

HEIDENHAIN iTNC 530 HSCI
1966 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
July 2013 6.8 The control loop 827
List of the nominal
position value
filters
The settings for the nominal position value filters are listed below by the MP
number.
MP1200 Nominal position value filter
Input: 0: Single filter
1: Double filter
2: HSC filter
3: Advanced HSC filter
MP1201 Nominal position value filter in the Manual, Handwheel,
Jog Increment, and Pass Over Reference Point operating
modes
Input: 0: Single filter
1: Double filter
MP1202 Predefined tolerance for Cycle 32
Input: 0.0000 to 3.0000 [mm]
MP1202.0 Tolerance at corners for movements at machining feed rate
MP1202.1 Tolerance at corners for movements at rapid traverse
MP1205 Reduction of the starting feed rate
Input: 0: Not active (fast, but somewhat less precise)
1: Active (slow, but likely more precise)
MP1210 Limit frequency for single filter
Input: 0.0 to 166.0 [Hz]
MP1211 Limit frequency for double filter
Input: 0.0 to 166.0 [Hz]
MP1212 Limit frequency for HSC filter
Input: 0.0 to 166.0 [Hz]
MP1213 Limit frequency for advanced HSC filter
Input: 0.0 to 166.0 [Hz]
MP1218.x Cutoff frequency for nominal position value filters or filters
of rotary axes (A, B, C)
Input: 0.0 to 166.0 [Hz]
0: Triangle filter (standard)
MP1222 Tolerance at curvature changes with HSC filter
Input: (only effective if MP7640 bit 4 = 0)
0: Do not include the tolerance
1: Include the tolerance
MP1223 Tolerance at curvature changes with advanced HSC-filter
Input: (only effective if MP7640 bit 4 = 0)
0: Do not include the tolerance
1: Include the tolerance

Table of Contents

Other manuals for HEIDENHAIN iTNC 530 HSCI

Related product manuals