948 HEIDENHAIN Technical Manual iTNC 530 HSCI
MP111 Position encoder input for the spindles
Input: 0: No position encoder
201 to 206: Position encoder inputs X201 to X206
MP111.0 Position encoder input for the first spindle
MP111.1 Position encoder input for the second spindle
MP3142 Line count of the spindle position encoder
Input: 100 to 100 000 [lines]
MP3143 Mounting configuration of the spindle position encoder
Input: 0: Position encoder immediately on the first spindle
1: Position encoder via transmission (ratio in MP3450.x and
MP3451.x); or X9 pin 14b : reference pulse
2: Position encoder via transmission (ratio in MP3450 and
MP3451); or X9 pin 14b: reference pulse release
3: Same as input value 1, except that the second reference
pulse is evaluated.
4: Reference-mark evaluation of the spindle via EnDat. The
encoder must be mounted directly (without transmission). No
reference pulse is necessary. A new reference-mark evaluation
via marker M4015 may only be performed at standstill.
5: The position encoder is mounted directly (same as input
value 0) and the transmission ratio is also evaluated. Entering
the value 5 results in the same behavior as that of software
version 340 49x-05 (rigid tapping will also be possible without a
position encoder on the spindle)!
MP3450.0-7 Number of spindle position-encoder revolutions for gear
ranges 1 to 8
Input: 0 to 65 535
0: No transmission
MP3451.0-7 Number of spindle position-encoder revolutions for gear
ranges 1 to 8
Input: 0 to 65 535
0: No transmission