July 2013 6.13 Integrated oscilloscope 997
Trigger threshold:
Enter the trigger threshold (you will find the appropriate units in the signals
table on 992):
Slope:
Define whether recording will be triggered with the rising (positive) or falling
(negative) edge.
Pre-trigger:
Recording begins at a time preceding the trigger time point by the value
entered here
Enter a value.
Delta trigger:
You can specify a second trigger threshold in the oscilloscope, which enables
you to use a value range to define the event triggering a recording. Depending
on the trigger edge and the first trigger value, you can determine whether a
trigger signal is output when the value range is reached or exceeded. The
inverse of the edge of the first trigger value is always selected as the active
trigger edge of the delta trigger. The delta trigger is given as a value relative to
the first trigger threshold. If a value of zero (0) is entered for the delta trigger
(default setting), then the delta trigger is off:
Enter the second trigger threshold (you will find the appropriate units in the
signals table on 992):