Oscilloscope display:
Press the OSCI soft key.
During recording, the selected signals are continuously displayed. After
recording ends, the memory contents are displayed. In addition, the signal
type and the resolution are displayed for each channel. The length of the
recorded range, with respect to the entire memory content, is shown as a bar
in the status field.
Move the cursor with the arrow keys to select the channel. The amplitude
of the selected channel as well as the time (with reference to start of
recording) are shown in the status field.
Activate a second cursor by pressing the CURSOR 1/2 soft key. The
oscilloscope displays the amplitude and time of this cursor. The time [s] of
the second cursor is shown with respect to the time point of the first cursor.
This function allows you to measure the acceleration time of an axis.
The cursor is located on the trigger point only if it has not been moved after
the measurement.
If the cursor has been moved, it will remain at the point of the time axis to
which it has been moved. The cursor does not return to the trigger point
until a trigger parameter has been changed.