10 – 108 HEIDENHAIN Service Manual iTNC 530 HSCI
Figure:
An overload generates an I2T error message on the machine, which in turn triggers an
EMERGENCY STOP. The error marker M 4178 changes from zero to one. On the time axis,
75 % before the error event are displayed.