11 – 132 HEIDENHAIN Service Manual iTNC 530 HSCI
Activating the
I/O-FORCE LIST
8 Press this soft key.
8 ON is highlighted; the I/O-FORCE LIST is active.
8 If you now exit the I/O-FORCE LIST with END, the following display will appear:
Saving the
I/O-FORCE LIST file
After you have created an I/O-FORCE LIST file, you can save it in order to be able to call it again at
a later date:
8 The I/O-FORCE LIST is displayed.
8 Press the PGMMGT key. --> The program management opens and the cursor is placed on the file
MAIN_PGM.FLT in the same path as the PLC main program.
8 Press the COPY soft key.
8 Enter a target file (e.g. Force123.wlt) and press the OK soft key.
Calling an
I/O FORCE LIST file
A saved I/O-FORCE LIST file can be called any time:
8 Open the I/O FORCE LIST function.
8 Press the PGMMGT key. --> The program management opens with the correct path.
8 Place the cursor on the saved I/O-FORCE LIST file (e.g., Force123.flt).
8 Press the ENT key. --> The file is loaded in the I/O-FORCE LIST function.
The text I/O-Force is active is shown only in the PLC mode.
If a machine operating mode is displayed on the monitor (e.g., Program Run, Full Sequence),
this information is not visible.
If you call the TABLE with the INPUTS and OUTPUTS, the "forced" inputs and outputs are displayed
in a different color (e.g., blue).