February 2012 3 – 19
Additional
information
As long as the machine parameter list is in the editor, no further code number can be entered.
I.e., first close the MP editor if you want to enter a new code number
Figure: As long as the text Machine parameter programming is displayed in the header, no further
code numbers are accepted (exception: NET123).
After you have entered the code number for the machine parameters the PLC tree can be seen
in the program management.
Only files with the extension .MP are displayed.
After entering the PLC code number, all files in the PLC tree can be seen and loaded in the editor.
However, to edit machine parameters you must press the MP EDIT soft key first.
Figure: The soft key MP EDIT must be pressed (or the code number 95148 entered) before you
are entitled to edit machine parameters.